HIGH VOLTAGE BREAKDOWN TESTERS (FLASH TESTERS)-10KV-30mA

HIGH VOLTAGE BREAKDOWN TESTERS (FLASH TESTERS)-10KV-30mA Image

HIGH VOLTAGE BREAKDOWN TESTERS

(FLASH TESTERS)

0 to 5 KV AC, 0 to 30 mA- ARUN & SONS – 214/217

0 to 10 KV AC, 0 to 30 mA- ARUN & SONS – 215/218

0 to 5 KV AC, 0 to 100 mA- ARUN & SONS  – 214A/219

 

High Voltage Breakdown Testers are useful for checking breakdown(flash-over) voltages of motors, transformers, pumps, chokes, coils, switches, connectors, plastics, rubbers, PCB’s insulation materials, electrical and electronic components etc. Automatic tripping facility, HT ON and HT OFF visual indications, HT ON buzzer, high voltage safety probe with push button enable features, provide operator’s safety. HT voltage and leakage current meters provide continuous readings, simultaneously.

TEST VOLTAGE :

0 to 5 KVAC in ARUN & SONS -214/217 ARUN & SOSN -214A/219

0 to 10 KVAC in ARUN & SONS -215/218

Test voltage is displayed on wide view moving coil type of panel meter. Reading accuracy is within ± 5%.

TRIPPING CURRENT LEVELS :

0 to 30 mAin ARUN & SONS -214/217 ARUN & SONS -215/218

0 to 100 mAin ARUN & SONS -214A/219

Tripping current levels can be set from 0 to maximum by front panel control. Actual value of leakage current is displayed on wide view moving coil type of panel meter. Reading accuracy is within ±5%.

SAFETY FEATURES : Whenever mains supply of the high voltage tester is turned ON, high voltage remains OFF and is enabled only when push button on safety probe is kept pressed and only when actual value of leakage current is less than the tripping current level setting.

HT on indication glows and buzzer sounds when high voltage is ON.

Acrylic probe with safety skirt keeps operator’s hand away from high voltage. Once high voltage is tripped, the same remains off unit push button of the high voltage is released and pressed again.

POWER REQUIREMENTS : 230 volts AC, ±10%, 50/60 Hertz.

200 VAin ARUN & SONS-214/217. 400 VA in ARUN & SONS -215/218 and 600 VA in

ARUN & SONS -214A/219.

SIZE AND WEIGHT :200mm (H) x 250mm (W) x 290mm (D) x 12,14 and 15 kgs for    – ARUN & SONS – 214/217 ARUN & SONS -215/218 ARUN & SONS-214A/219 respectively.

STANDARD ACCESSORIES : Instruction Manual.

HIGH VOLTAGE BREAKDOWN TESTERS (FLASH TESTERS)-10KV-30mA

HIGH VOLTAGE BREAKDOWN TESTERS (FLASH TESTERS)-10KV-30mA Image

HIGH VOLTAGE BREAKDOWN TESTERS

(FLASH TESTERS)

0 to 5 KV AC, 0 to 30 mA- ARUN & SONS – 214/217

0 to 10 KV AC, 0 to 30 mA- ARUN & SONS – 215/218

0 to 5 KV AC, 0 to 100 mA- ARUN & SONS  – 214A/219

 

High Voltage Breakdown Testers are useful for checking breakdown(flash-over) voltages of motors, transformers, pumps, chokes, coils, switches, connectors, plastics, rubbers, PCB’s insulation materials, electrical and electronic components etc. Automatic tripping facility, HT ON and HT OFF visual indications, HT ON buzzer, high voltage safety probe with push button enable features, provide operator’s safety. HT voltage and leakage current meters provide continuous readings, simultaneously.

TEST VOLTAGE :

0 to 5 KVAC in ARUN & SONS -214/217 ARUN & SOSN -214A/219

0 to 10 KVAC in ARUN & SONS -215/218

Test voltage is displayed on wide view moving coil type of panel meter. Reading accuracy is within ± 5%.

TRIPPING CURRENT LEVELS :

0 to 30 mAin ARUN & SONS -214/217 ARUN & SONS -215/218

0 to 100 mAin ARUN & SONS -214A/219

Tripping current levels can be set from 0 to maximum by front panel control. Actual value of leakage current is displayed on wide view moving coil type of panel meter. Reading accuracy is within ±5%.

SAFETY FEATURES : Whenever mains supply of the high voltage tester is turned ON, high voltage remains OFF and is enabled only when push button on safety probe is kept pressed and only when actual value of leakage current is less than the tripping current level setting.

HT on indication glows and buzzer sounds when high voltage is ON.

Acrylic probe with safety skirt keeps operator’s hand away from high voltage. Once high voltage is tripped, the same remains off unit push button of the high voltage is released and pressed again.

POWER REQUIREMENTS : 230 volts AC, ±10%, 50/60 Hertz.

200 VAin ARUN & SONS-214/217. 400 VA in ARUN & SONS -215/218 and 600 VA in

ARUN & SONS -214A/219.

SIZE AND WEIGHT :200mm (H) x 250mm (W) x 290mm (D) x 12,14 and 15 kgs for    – ARUN & SONS – 214/217 ARUN & SONS -215/218 ARUN & SONS-214A/219 respectively.

STANDARD ACCESSORIES : Instruction Manual.