DC POWER SUPPLY (SINGLE VARIABLE OUTPUT)
DC POWER SUPPLIES
SINGLE VARIABLE OUTPUT
0 to 5 volts, 0 to 2 amps TESTRONIX 30B 0 to 5 volts, 0 to 5 amps TESTRONIX 30C 0 to 5 volts, 0 to 10 amps TESTRONIX 30D 0 to 16 volts, 0 to 2 amps TESTRONIX 34B 0 to 16 volts, 0 to 5 amps TESTRONIX 34C 0 to 16 volts, 0 to 10 amps TESTRONIX 34D 0 to 16 volts, 0 to 20 amps TESTRONIX 34E 0 to 32 volts, 0 to 1 amps TESTRONIX 92A 0 to 32 volts, 0 to 2 amps TESTRONIX 92B 0 to 32 volts, 0 to 5 amps TESTRONIX 92C 0 to 32 volts, 0 to 10 amps TESTRONIX 92D 0 to 65 volts, 0 to 1 amps TESTRONIX 36A 0 to 65 volts, 0 to 2 amps TESTRONIX 36B 0 to 65 volts, 0 to 5 amps TESTRONIX 36C 0 to125 volts,0 to 1 amps TESTRONIX 31A 0 to 125 volt,0 to 2 amps TESTRONIX 31B
OUTPUT VOLTAGES : The output voltage is continuously adjustable by coarse and fine controls and is displayed on 3 ½ digit, LED display of 12.5 mm height with accuracy of ±0.5% ±2 least counts. (Voltmeters in models 30C/ 30D/ 92A/ 92B/ 92C/ 92D/ 36A/ 36B/ 36C have 3 digit displays.) Output voltage can be floated on any live voltage or any of the two voltage terminals can be grounded to get positive or negative voltage.
LOAD CURRENT : Load current is displayed on 3½ digit, LED display of 12.5mm height, with accuracy pf ±0.5% ± least counts. (Current meters in models 30C/ 34C/ 36C have 3 digit displays.) Maximum value of output current can be limited from less than 10% to 100% of the capacity by continuously adjustable coarse and the controls.
PROTECTION : Short circuit and overload protected. Constant voltage constant current type of regulation provides constant voltage if load current is less than current limit setting. If load tries to draw more current than the value of current limit setting, current becomes constant at the limit setting and output voltage comes down to limit the current at the limit setting value.
REGULATION : ±0.05% from no load to full load and for ±10% variations in input mains voltage.
RIPPLES : Less than 3 milli volts rms.
POWER REQUIREMENTS : 230 ±10% VAC, 50/60 herts. Power consumption is 1.5 times multiple of maximum voltage rating and load current drawn.
SIZE AND WEIGHT :125mm (H) x 125mm(W) x 270mm(D), 3.5kgs for 30C/34B/92A. 135mm (H) x 195mm(W) x 270mm(D), 5kgs for 30D/34C/92B/36A/36B. 135mm (H) x 360mm(W) x 270mm(D), 9.5kgs for 34D/92C 225mm (H) x 255mm(W) x 300mm(D), 14kgs for 92D/36C
STANDARD ACCESSORIES : Test leads and instruction manual.
DC POWER SUPPLY (SINGLE VARIABLE OUTPUT)
DC POWER SUPPLIES
SINGLE VARIABLE OUTPUT
0 to 5 volts, 0 to 2 amps TESTRONIX 30B 0 to 5 volts, 0 to 5 amps TESTRONIX 30C 0 to 5 volts, 0 to 10 amps TESTRONIX 30D 0 to 16 volts, 0 to 2 amps TESTRONIX 34B 0 to 16 volts, 0 to 5 amps TESTRONIX 34C 0 to 16 volts, 0 to 10 amps TESTRONIX 34D 0 to 16 volts, 0 to 20 amps TESTRONIX 34E 0 to 32 volts, 0 to 1 amps TESTRONIX 92A 0 to 32 volts, 0 to 2 amps TESTRONIX 92B 0 to 32 volts, 0 to 5 amps TESTRONIX 92C 0 to 32 volts, 0 to 10 amps TESTRONIX 92D 0 to 65 volts, 0 to 1 amps TESTRONIX 36A 0 to 65 volts, 0 to 2 amps TESTRONIX 36B 0 to 65 volts, 0 to 5 amps TESTRONIX 36C 0 to125 volts,0 to 1 amps TESTRONIX 31A 0 to 125 volt,0 to 2 amps TESTRONIX 31B
OUTPUT VOLTAGES : The output voltage is continuously adjustable by coarse and fine controls and is displayed on 3 ½ digit, LED display of 12.5 mm height with accuracy of ±0.5% ±2 least counts. (Voltmeters in models 30C/ 30D/ 92A/ 92B/ 92C/ 92D/ 36A/ 36B/ 36C have 3 digit displays.) Output voltage can be floated on any live voltage or any of the two voltage terminals can be grounded to get positive or negative voltage.
LOAD CURRENT : Load current is displayed on 3½ digit, LED display of 12.5mm height, with accuracy pf ±0.5% ± least counts. (Current meters in models 30C/ 34C/ 36C have 3 digit displays.) Maximum value of output current can be limited from less than 10% to 100% of the capacity by continuously adjustable coarse and the controls.
PROTECTION : Short circuit and overload protected. Constant voltage constant current type of regulation provides constant voltage if load current is less than current limit setting. If load tries to draw more current than the value of current limit setting, current becomes constant at the limit setting and output voltage comes down to limit the current at the limit setting value.
REGULATION : ±0.05% from no load to full load and for ±10% variations in input mains voltage.
RIPPLES : Less than 3 milli volts rms.
POWER REQUIREMENTS : 230 ±10% VAC, 50/60 herts. Power consumption is 1.5 times multiple of maximum voltage rating and load current drawn.
SIZE AND WEIGHT :125mm (H) x 125mm(W) x 270mm(D), 3.5kgs for 30C/34B/92A. 135mm (H) x 195mm(W) x 270mm(D), 5kgs for 30D/34C/92B/36A/36B. 135mm (H) x 360mm(W) x 270mm(D), 9.5kgs for 34D/92C 225mm (H) x 255mm(W) x 300mm(D), 14kgs for 92D/36C
STANDARD ACCESSORIES : Test leads and instruction manual.